Home > I O Error > Iec030i B37-04

Iec030i B37-04

Contents

THE NUMBER OF BUFFERS SPECIFIED IN THE BUFFER POOL CONTROL BLOCK IS NOT THE SAME AS THAT SPECIFIED IN THE DCBBUFNO. EUT=YES WAS SPECIFIED ON THE SETFRR MACRO. DURING EOV PROCESSING, IT WAS DISCOVERED THAT THE EXPIRATION DATE (FROM THE HDR1 LABEL OF THE FIRST DATASET CURRENTLY ON THE SPECIFIED VOLUME) HAD NOT PASSED. SEGMENT MODE IS IMPLIED.

NOT ENOUGH REAL STORAGE AVAILABLE TO BACK A MINIMUM NUMBER OF VSM CELLS (IN LSQA) DURING LOCAL CELL POOL EXPANSION. S213 - 58 - AN ATTEMPT WAS MADE TO CHANGE THE DSORG OF AN SMS-MANAGED DATA SET TO UNMOVEABLE WHICH IS NOT ALLOWED ON SMS-MANAGED VOLUMES. S0B0 - 10 - INVALID LENGTH (0 OR NEGATIVE FOR ASSIGN LOCATE OR ATTEMPTING TO READ OR WRITE A RECORD, WHICH IS NOT 176 BYTES, IN MOVE MODE). S171 - 04 - THE ERROR WAS DETECTED BY THE PAGE SERVICES ROUTINE. http://www.ibm.com/support/docview.wss?uid=swg21227089

Iec030i B37-04

If the manuals are available, the error description and corrective procedure are often impossible to interpret. S022 - THE VPSS ENCOUNTERED A MISSING DEVICE END ON CONTROL PORT 0. S16E - THE CONTROL PROGRAM REQUESTED THAT A DEBCHK FUNCTION BE PERFORMED ON A DATA EXTENT BLOCK OBTAINED FROM THE DCB PASSED BY THE PROGRAM.

S004 - 03 - CONFLICTING ACCESS METHODS SPECIFIED. S240 - AN ERROR OCCURRED DURING EXECUTION OF A RDJFCB MACRO. Check the file description 06x Error closing a file 09x File opening problem (usually related to a print file) 0C1, 0C2, 0C3 Operation program check Invalid or missing DD statement Reading Iec028i 837-08 Firstly, if the DASD volume to which the system has assigned one of the program's output datasets does not have enough available space to allow the necessary secondary allocations to be

S0E0 - 2D - A PRIVATE ACCESS LIST ENTRY IS SPECIFIED, AND THE CURRENT EAX IS NOT AUTHORIZED TO THE TARGET ADDRESS SPACE. System Abend Code = B37, Reason Code = 00000004 RCT RECOVERY RECORDS THE ERROR INSYS1.LOGREC, PERFORMS RESOURCE CLEAN-UP, REQUESTS A SYS1.DUMP OF THE ADDRESS SPACE AND THEN REQUESTS ADDRESS TERMINATION. S30A - 18 - PRIVATE AREA SUBPOOL NOT FOUND. http://ibmmainframes.com/about51994.html S137 - 24 - A SPECIFIC VOLUME SERIAL NUMBER WAS SPECIFIED FOR THE SECOND OR SUBSEQUENT VOLUME OF AN OUTPUT DATASET ON MAGNETIC TAPE.

S240 - 08 - A RDJFCB MACRO INSTRUCTION WAS ISSUED, BUT NO EXLST ADDRESS WAS FOUND IN THE DCB. Iec070i 209-220 THE LENGTH VALUE OF THE RDW IS EITHER: LESS THAN 4, GREATER THAN 32,767, GREATER THAN THE BLOCKSIZE SPECIFIED IN THE DCB, OR LESS THAN 5 IF ASA CONTROL CHARACTERS ARE ACCEPTABLE TYPES ARE ADD, DELETE, VERIFY, AND PURGE. IF THE REGISTER 15 RETURN CODE IS AVAILABLE, SUPPLY IT IN THE S233 OPERAND FOR MORE SPECIFIC INFORMATION: H ABEND O(S233-RC) S233 - 04 - THE ADDRESS OF THE PARAMETER LIST

System Abend Code = B37, Reason Code = 00000004

THE DATA BEING PAGED IN OR SWAPPED IN IS LOST.- A REAL STORAGE MANAGEMENT ROUTINE OR ANOTHER SYSTEM ROUTINE PERFORMING A SERVICE FOR RSM SUFFERED AN INTERMEDIATE ERROR. http://forums.informationbuilders.com/eve/forums/a/tpc/f/7971057331/m/3781086603 ERROR ID: IEC031I 2. Iec030i B37-04 S0D3 - A PROGRAM CHECK, INTERRUPTION CODE 19 X'13' (SPECIAL OPERATION ERROR) HAS OCCURRED. E37-04 USUALLY CAUSED BY UNINTENTIONAL BRANCH TO INVALID INSTRUCTION.

S002 - 7C - POINT DETECTED THAT INFORMATION CONCERNING THE MEMBER BEING ACCESSED IS NOT FOUND IN THE PACB. S031 - SPACE REQUESTED NOT AVAILABLE, DECREASE THE SPACE ALLOCATION S032 - DURING A BISAM OR QISAM OPEN DCBMACRF WAS NOT VALID FOR ISAM. S314 - 08 - AN I/O ERROR OCCURRED READING A FORMAT-1 DSCB DURING EXECUTION OF A CLOSE MACRO AND STANDARD USER LABELS WERE SPECIFIED. TOINCREASE THE TABLE SIZE BY THE REQUIRED INCREMENT OF 24 WOULD CAUSE THE TABLE TO EXCEED ITS MAXIMUM SIZE. Ifg0554a

Space Allocation on z/OS The SPACE parameter specifies the primary and secondary allocation. Check the JCL STEPLIB or JOBLIB statements to be sure they define the library containing the requested program. If you are not automatically redirected please click here. {{message.agentProfile.name}} will be helping you today. S240 - 0C - A RDJFCB MACRO INSTRUCTION WAS ISSUED, BUT NO JFCB EXIT WAS SPECIFIED IN THE DCB EXIT LIST.

View Profile Transfered to {{message.agentProfile.name}} {{message.agentProfile.name}} joined the conversation {{message.agentProfile.name}} left the conversation Your chat with {{$storage.chatSession.messages[$index - 1].agentProfile.name}} has ended. B37 Error This information is useful when contacting support services. RACF only allows you to access datasets with a high level qualifier the same as your userid or which you have been explicitly given access permission to by the owner of

S079 - RCT (REGION CONTROL TASK) ATTENTION EXIT PROCESSING HAS RECEIVED AN UNACCEPTABLE RETURN CODE FROM AN INVOKED ROUTINE AND CANNOT CONTINUE PROCESSING.

International readers based in the US and other countries can click here to purchase the e-book.

mainframegeek Search Primary Menu Skip to content Abend Codes and explanationFree Mainframe user ID.AboutCOBOL S23E - THE ERROR WAS DETECTED DURING EXECUTION OF A DETACH MACRO INSTRUCTION. T6EXIT MACRO POINTS TO SRB WHERE SRBASCB IS NOT HOME ASCB. Iec032i MULTI-VOLUME VSAM FILES CANNOT BE OPENED WITH A DCB.

DMH610Z is used to create a list of libraries and members which are to be analyzed and loaded in the database. Check to determine if your program is looping. IN THE ABNORMAL TERMINATION DUMP, THE TCB FIELD TCBEXCPD (AT OFFSET C0) POINTS TO THE EXCP PROBLEM DETERMINATION AREA. S013 - 0C - A BUFFER LENGTH OF 0 WAS SPECIFIED FOR A BDAM DATASET FOR WHICH DYNAMIC BUFFERING WAS REQUESTED.

The actual jobname, procedure name, and stepname for your job will appear in the indicated locations in the message. THE VOLUME SERIAL NUMBERS ON THE DD STATEMENT WERE NOT SPECIFIED IN THE SAME ORDER THAT THE DATASET WAS CREATED. ERROR ID: IEC143I 2.