If you have any questions, then please Write a Comment below! But what if say you have just 2 drives in RAID 1, bay 0 and bay 1 and let's say your bay 1 drive failed, and the drive you swapped in I've gotten drives shipped direct from Seagate with data on them already! 0 This discussion has been inactive for over a year. HP Proliant Server Troubleshooting Guide ► October (29) ► September (22) ► August (8) ► July (1) ► June (8) ► May (4) ► April (7) ► March (7) ► February http://permamatrix.net/hp-proliant/hp-proliant-post-error.html

Your cache administrator is webmaster. I installed them a few months ago and setup the 2nd datastore on my ESXi server but I have not placed any VMs or data at all on these drives. Also, if it is consistantly occuring even during a clean reboot; you should check the firmware and driver of the array controller and apply updates as needed. 0 Message Author These disks have no data on them. https://community.hpe.com/t5/ProLiant-Servers-ML-DL-SL/HP-Proliant-Post-Error-1792-Drive-Array-Reports-Valid-Data-found/td-p/5294361

Power was then restored within several days, and the data in the array accelerator was flushed to the drive array.Action: No action is required. The other disks in that array are probably the same age and have the same usage and so are also likely to experience a failure. Perform orderly system shutdowns to avoid leaving data in the array accelerator.http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?lang=en&cc=us&objectID=c01451072>>>>>>>>>>>>>>>>>Regarding "mpx.vmhba5:C0:T0:L0" as I understand mpx.vmhba5:C0:T0:L0 is Adapter: vmhba5 Channel: 0 Target: 0 LUN: 0I had one case where the No data has been lost.

Showing results for  Search instead for  Do you mean  Menu Categories Solutions IT Transformation Internet of Things Topics Big Data Cloud Security Infrastructure Strategy and Technology Products Cloud Integrated Systems Networking If it's not critical or not production then I have in the past (with good backups) gone into the RAID manager and forced the drive back online and it has worked. But does migrating to a cloud fax solution mean you will no longer be able to send or re… eFax How to change your primary email address Video by: Kyle Hi I have found the same issues on HP forums http://h30499.www3.hp.com/t5/ProLiant-Servers-Netservers/OST-Error-1792-Drive-Array-Reports-Valid-Data-Found-in-Array/m-p/394303http://www.virmansec.com/blogs/skhairuddin Marked as answer by Brent HuModerator Friday, February 04, 2011 7:56 AM Thursday, February 03, 2011 6:27 AM Reply | Quote

the first thing i would do, when you have the window, is to actually POWER the server OFF. Covered by US Patent. Printer Migrator Terminal 2008 Server - Install mode Microsoft Dynamics GP - Add-on Software Blackberry Torch - Enterprise Activation HP Proliant - Post Error: 1792 Drive Array Reports... and still the server is restarting.

what are you doing?  You should not be posting again until the drive is on its way.  Seriously, you are at risk right now. Join Now For immediate help use Live now! Join & Ask a Question Need Help in Real-Time? And just because your drive is new, or even refurb from the manufacturer...

Shop floor hub Had to move a building that was acting as our hub for the devices out on the shop floor. https://community.spiceworks.com/topic/105176-post-error-1792-drive-array-reports-valid-data-found-in-array-accelerator WHAT DRIVE? Subscribe to our monthly newsletter for tech news and trends Membership How it Works Gigs Live Careers Plans and Pricing For Business Become an Expert Resource Center About Us Who We The server is running Windows Small Business Server 2003.Can anyone please explain me why the POST error?Regards,Edgar Santos Regards,Edgar Santos IML.png ‏116 KB Smart array.png ‏113 KB ACU.png ‏102 KB 0

Experts Exchange Setup SMTP relay to office 365 Video by: acox65807 how to add IIS SMTP to handle application/Scanner relays into office 365. his comment is here So that is the most likely case?  What would happen if I restarted the host server? Limey wrote: if it were me I would plan on a restart once the new drive comes in. Join our community for more solutions or to ask questions.

No data has been lost. The name , IP and the WWN ID’s used here are not the real ones. Suggested Solutions Title # Comments Views Activity No bootable device found 12 42 124d How to configure Link-Aggregration on HP A5500 Switch 2 48 111d How to clone Linux server? 15 this contact form Please try the request again.

Want to take bets on which array is wiped and which is rebuilt? Thx. 0 Kudos Reply juan quesada Respected Contributor [Founder] Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight Print Email to a Friend Report Inappropriate Content ‎06-22-2010 08:32 AM ERROR The requested URL could not be retrieved The following error was encountered while trying to retrieve the URL: http://0.0.0.10/ Connection to 0.0.0.10 failed.

Creating your account only takes a few minutes.

Perform orderly system shutdowns to avoid leaving data in the array accelerator.1792 Error Message Error Message: 1792-Drive Array Reports Valid Data Found in Array Accelerator......Data will automatically be written to drive Justin2100 wrote:   Scott Alan Miller wrote: Justin2100 wrote: What if I just remove the drive?  That will be the same as if it completely died.  Not what you want in Our organization moved from a legacy setup of ten servers to a single powerful server running Windows Hyper-V Server 2012. Privacy statement  © 2016 Microsoft.

Ordered a Rack Mount Enclosure, patch panel, switch and a battery backup for our new hub. Power was then restored within several days, and the data in the array accelerator was flushed to the drive array.Action: No action is required. The following information is part of the event: \Device\RaidPort0."....................................................two years ago, had the same issue and the same error. http://permamatrix.net/hp-proliant/hp-proliant-ml350-g4-specs.html Just my luck.

These disks have no data on them. Community ProLiant Servers (ML,DL,SL) CommunityCategoryBoardUsers turn on suggestions Auto-suggest helps you quickly narrow down your search results by suggesting possible matches as I would try going into the RAID manager and run diagnostics on the drive. If it comes up bad then replace, if it comes up OK then I would try and push it back online.

In the Array Configuration Utility is the same, no errors, no problems, the battery is OK (was recently replaced).The array controller is a E200i with the latest version 1.86. Join Now Hello -  Today, I noticed there was an amber light on disk 6 of my 8 disk chassis for an HP DL380 G5 server. Join the community Back I agree Powerful tools you need, all for free. We keep at least 1 spare for every drive type we have, then order a new one if we use it 0 Mace OP Limey Jul 21, 2010

Not a member? The system returned: (22) Invalid argument The remote host or network may be down. I haven't been able to order the replacement drive yet, but again disks 1-5 are in a RAID 10 (this has production data that appears to be unaffected for now)  Disks All rights reserved.Newsletter|Contact Us|Privacy Statement|Terms of Use|Trademarks|Site Feedback TechNet Products IT Resources Downloads Training Support Products Windows Windows Server System Center Browser   Office Office 365 Exchange Server   SQL Server

Community ProLiant Servers (ML,DL,SL) CommunityCategoryBoardUsers turn on suggestions Auto-suggest helps you quickly narrow down your search results by suggesting possible matches as Screen shot enclosed.What has to be done?Kind regards,Arthur Heller/Atos Origin/Vienna. 296935.pdf ‏85 KB 0 Kudos Reply All Forum Topics Previous Topic Next Topic 4 REPLIES Víctor Cespón Honored Contributor [Founder] Options Microsoft Customer Support Microsoft Community Forums HP ProLiant サーバー - エラー番号17xxのPOSTエラー (特に処置不要なメッセージ、エラーコード) についてDocument ID:   n/aCreated:   n/aUpdated:   n/a 対象条件 機種 HP ProLiant サーバー オプション HP Smartアレイコントローラー 解説 ここでは、ProLiantサーバーのPOST時に表示されるエラー番号17xxで始まるメッセージのうち、特に処置不要なエラーコードついてご案内します。 これらのエラーコードについては、設定変更やご利用環境の変化等を通知するメッセージですので特に操作等を行う必要はありません。 Connect with top rated Experts 15 Experts available now in Live!

if it was a 320gb 10k then I would replace it with a new 320gb 10k. Showing results for  Search instead for  Do you mean  Menu Categories Solutions IT Transformation Internet of Things Topics Big Data Cloud Security Infrastructure Strategy and Technology Products Cloud Integrated Systems Networking You may get a better answer to your question by starting a new discussion. Then, boot to a firmware update CD, and update all your device firmwares and microcodes.