Home > Hp Proliant > Hp Proliant Ml350 Error 1611

Hp Proliant Ml350 Error 1611

Join UsClose Skip navigation UploadSign inSearch Loading... Server is old and we could not find documentation. After the error appears, there's a 5 second countdown, after which it shuts off and powers up again after a few seconds. Nov 21, 2008 | HP Compaq ProLiant DL580 G4 (430811001)... http://permamatrix.net/hp-proliant/hp-proliant-1611-fan-failure.html

X32 version http://h20000.www2.hp.com/bizsupport/TechSupport/SoftwareDescription.jsp?lang=en&cc=us&prodTypeId=3709945&prodSeriesId=3884098&prodNameId=3884099&swEnvOID=1005&swLang=8&mode=2&taskId=135&swItem=MTX-00b1501bdf9a4ddda9353d075e x64 version http://h20000.www2.hp.com/bizsupport/TechSupport/SoftwareDescription.jsp?lang=en&cc=us&prodTypeId=3709945&prodSeriesId=3884098&prodNameId=3884099&swEnvOID=4024&swLang=8&mode=2&taskId=135&swItem=MTX-3f97b02184724797ac2827ebdc you can check the array and controller using ACU (array config util) Posted on Feb 28, 2011 Helpful 0 Not Helpful Flag You can't post HPE Technology 8,914 views 4:11 Configuring & provisioning P2000 G3 MSA - Duration: 3:25. Is foreign stock considered more risky than local stock and why? The ILO network connect allows you to use another PC on the same network to access this system (like a remote control via VNC or RDP) even if it won't power https://community.hpe.com/t5/ProLiant-Servers-Netservers/ML350-error-1611-drive-Fan-failure/td-p/554882

I had to do a hard shutdown today because it would not respond to any form of control or a soft shutdown via... This document is subject to change without notice. Given about 3 minutes will see a fan as 'not working', while still working. Ask Anonymously Popular Questions 1 Answer 02A2: BMC System Event Log(SEL) Full HP Compaq ProLiant ML110 G4... 3 Answers I need to download an hp proliant ml110 driver for window xp

Sign in to report inappropriate content. I am checking the Compaq forums now. Your answer needs to include more details to help people. HP ProLiant Computer Servers HP Computer Servers 1611 fan failure g6 fan View Less » 1,157 people viewed this question Ask a Question Usually answered in minutes!

Some after-market part won't provide the right data to the motherboard. They are all spinning loud n' clear, and best, no more amber LED or thermal shutdown! I can not get passed the 1611 error. https://community.hpe.com/t5/ProLiant-Servers-ML-DL-SL/Proliant-1600-1611-Cpu-Fan-failure-detected/td-p/3248031 RE: "1611 CPU Fan Failure" bootup error Guest (visitor) (OP) 27 Aug 02 23:56 Yes I changed the fan at the back.Thank you very much for your advice!

I believe this is sometimes the reason for false 'failed fan' reports. Does anyone know what needs to be replaced or what I may try next? Remove Advertisements Sponsored Links TechSupportForum.com Advertisement 05-05-2012, 04:12 AM #2 buzza24 Registered Member Join Date: Mar 2008 Location: Sydney, NSW, Australia Posts: 154 OS: Windows 10 There It was the fan board that needed to be replaced.

I would call up the parts place I referred to earlier in the thread and ask for a fan that has a pinout like I described.

Shared fans 4 and 7 each provide airflow for two zones. I looked closer at my fan setup and noticed each original fan wire set had a female-to-male extension of the wires with what looks like a diode heat-shrinked in. Watch Queue Queue __count__/__total__ Find out whyClose 1610 1611 Errors at POST on HP ProLiant Server HPE Technology SubscribeSubscribedUnsubscribe Loading...

Power on the server and allow it to idle for 3 minutes. his comment is here Include an image. RE: "1611 CPU Fan Failure" bootup error Sunny79 (MIS) 27 Aug 02 20:33 That visitor above is me by that way, sorry wasn't logged in.If you have any questions feel free If that doesn't work: Remove all power supplies from the chassis Turn DIP switches #1, 5 and 6 switch on.

Close Box Join Tek-Tips Today! If you have warranty on this server go ahead and have the processor cage replaced and your issue should be taken care of.Good luck. I orginially had connected it to my PC via USB 2.0 and formatted the entire drive and everything seemed to be in working order. this contact form I read in one post that there is a jump to change the required number of fans but it didn't say which one.

DETAILS Both primary and redundant fans in the ProLiant DL380 G3 server must be configured to meet specific requirements in order to avoid the error messages above and in some instances, I installed it using the sensor from the old fan. HP ProLiant DL360 G3 Server error 1611 thermal shutdown This is a discussion on HP ProLiant DL360 G3 Server error 1611 thermal shutdown within the Windows Servers forums, part of the

After that I decided to connect the drive via eSATA because of the speed increase.

If you can get into ILO via web browser: https://ipddress of ilo, you can check the Integrated log, which can shed some light on any failures. Insert all power supply units. All primary fan locations (2, 4, 5, 6 and 7) must be populated with a fan before the redundant fan locations (1, 3, or 8) are populated. Sign in Share More Report Need to report the video?

He said he'd sold hundreds of these and never had this problem.He said he had the exact make, model, and amperage that I had in there originally, so I had him HPE Technology 1,023 views 1:37 HP StorageWorks EVA 10.x Collecting Controller Event Logs - Duration: 1:57. Transcript The interactive transcript could not be loaded. http://permamatrix.net/hp-proliant/hp-proliant-ml350-g4-specs.html Please help.

Every suggestion tells me to replace the fan. Jul 23, 2012 | HP ML350 G6 (517430005) Server 1 Answer Compaq dl380 g1 - 1611 Power Supply 1 Fan Failure Detected it only ur fan problem which one of the Still, what happens is they stop spinning when the system comes on. Register now while it's still free!

I'll rob the parts that are good and dispose of properly. Thank you for taking the time to read my post and supply a link for some info. Talk With Other Members Be Notified Of ResponsesTo Your Posts Keyword Search One-Click Access To YourFavorite Forums Automated SignaturesOn Your Posts Best Of All, It's Free! Not sure how this can be a problem with the board as described above ??

The email address entered is already associated to an account.Login to post Please use English characters only. You would have use an add-on card. To stop the shutdowns, you can disable the thermal shutdown. You can mark the thread as solved in the thread tools. __________________ From time to time, we have been tempted to believe that society has become too complex to be managed

Loading...Oops :Please try again.